Akces-Med Poland · 3. Dynamic Standing Frames
ACTIVALL Dynamic standing frame
No reviews yet — write the first oneThe ACTIVALL™ dynamic standing frame supports daily rehabilitation at home or in clinics. Lightweight and adjustable, it helps users of all ages stand, walk, and gain independence while ensuring comfort and safety.

| Symbol | Measurement | Unit | Size 1 | Size 2 | Size 3 | Size 4 | Size 5 |
|---|---|---|---|---|---|---|---|
| W | Indicative user height** | [cm] | 70 – 100 | 100 – 130 | 110 – 150 | 110 – 170 | 140 – 200 |
| A/A1 | Pelvic/chest support width | [cm] | 26 | 28 | 31 | 37 | 42 |
| C | Pelvic support height | [cm] | 44 – 60 | 66 – 82 | 77 – 102 | 83 – 112 | 98 – 120 |
| C1 | Chest support height | [cm] | 52 – 70 | 77 – 95 | 89 – 116 | 92 – 126 | 108 – 143 |
| B/B1 | Pelvic/chest support depth* | [cm] | 22 | 25 | 27 | 29 | 35 |
| Pelvic/chest support perimeter | [cm] | 87 | 97 | 106 | 124 | 144 | |
| Maximum user weight | [kg] | 25 | 40 | 60 | 80 | 95 |
Note: Measurement tolerance range is +/- 1 cm / ½ in.
* Measured without harness stabilizing the hips.
** The value cannot be main factor for selection of product size.
WEIGHT AND DIMENSIONS
| Measurement | Unit | Size 1 | Size 2 | Size 3 | Size 4 | Size 5 |
|---|---|---|---|---|---|---|
| Width | [cm] | 59 | 60 | 63 | 66 | 74 |
| Length | [cm] | 73 | 84 | 84 | 91 | 98 |
| Height | [cm] | 54 | 79 | 90 | 96 | 112 |
| Weight | [kg] | 13,5 | 16,5 | 18 | 20,5 | 23 |
Note: Measurement tolerance range is +/- 1 cm / ½ in.
Note: Approximate values, depending on the product configuration.
As a part of our permanent product improvement, Akces-MED reserves the right to change design and specifications without notice. Further, not all options and features offered are compatible with all configurations. Please refer to the user instruction manual for more information.
Description
As far this dynamic standing frame is concerned, it is highly beneficial to the process of daily rehabilitation which takes place not only in hospitals and rehabilitation wards but also in user’s house. This device enables the user to stand and walk. Moreover, children are able to take first steps and adults can either keep or regain fitness.
Key Benefits
- Stable structure — The device ensures adequate stability and safety of user.
- Independence — Patient can upright by himself or walking independently.
- Easy to use — Intuitive way of adjustment and easy assembly.
- 2 in 1 — The product has 2 utility functions for use in 1 single device. Dynamic and static function.
- 24Month Warranty — We offer 24-month warranty on the product. We also provide after sales service.
Both light and stable frame is helpful in independent relocation in this device with slight involvement of the user. The correct adjustment of braces makes the user feel secure as well as comfortable during performing activities. Furthermore, this product may be used by users in different age groups due to a vast array of sizes.
ACTIVALL™ plays a significant role because of the fact that user has the possibility of gaining new experience and, more to the point, being independent as far as possible.
Special features

Product Details
- Brand
- Akces-Med Poland
- Distributor
- Al Anwar Medical Equipment Trading L.L.C.
- Product Code
- ACTIVALL
- Customer Care Phone
- 04 294 6270
- Customer Care Email
- [email protected]
- Return & Refund
- 7-day return or exchange from date of delivery.
- Care Instructions
- Follow the manufacturer's user manual for daily use, adjustment and cleaning (see the brochure below).
Size Chart

| Symbol | Measurement | Unit | Size 1 | Size 2 | Size 3 | Size 4 | Size 5 |
|---|---|---|---|---|---|---|---|
| W | Indicative user height** | [cm] | 70 – 100 | 100 – 130 | 110 – 150 | 110 – 170 | 140 – 200 |
| A/A1 | Pelvic/chest support width | [cm] | 26 | 28 | 31 | 37 | 42 |
| C | Pelvic support height | [cm] | 44 – 60 | 66 – 82 | 77 – 102 | 83 – 112 | 98 – 120 |
| C1 | Chest support height | [cm] | 52 – 70 | 77 – 95 | 89 – 116 | 92 – 126 | 108 – 143 |
| B/B1 | Pelvic/chest support depth* | [cm] | 22 | 25 | 27 | 29 | 35 |
| Pelvic/chest support perimeter | [cm] | 87 | 97 | 106 | 124 | 144 | |
| Maximum user weight | [kg] | 25 | 40 | 60 | 80 | 95 |
Note: Measurement tolerance range is +/- 1 cm / ½ in.
* Measured without harness stabilizing the hips.
** The value cannot be main factor for selection of product size.
WEIGHT AND DIMENSIONS
| Measurement | Unit | Size 1 | Size 2 | Size 3 | Size 4 | Size 5 |
|---|---|---|---|---|---|---|
| Width | [cm] | 59 | 60 | 63 | 66 | 74 |
| Length | [cm] | 73 | 84 | 84 | 91 | 98 |
| Height | [cm] | 54 | 79 | 90 | 96 | 112 |
| Weight | [kg] | 13,5 | 16,5 | 18 | 20,5 | 23 |
Note: Measurement tolerance range is +/- 1 cm / ½ in.
Note: Approximate values, depending on the product configuration.
As a part of our permanent product improvement, Akces-MED reserves the right to change design and specifications without notice. Further, not all options and features offered are compatible with all configurations. Please refer to the user instruction manual for more information.
Between two sizes? Choose the larger one, or chat with our fitting team on WhatsApp before you order.
Indications & Contraindications
INDICATIONS
It is recommended in the following cases:
- Cerebral palsy (CP) – various types and forms.
- Brain and spinal cord injuries of various etiologies with limb paresis, severe balance disturbances, and coordination impairments.
- Demyelinating diseases (multiple sclerosis – MS, amyotrophic lateral sclerosis – ALS, and others).
- Meningocele.
- Muscle diseases with paresis and paralysis (including dystrophy, myasthenia gravis, polymyositis).
- Genetic syndromes with limb paresis.
- Degenerative and metabolic diseases of the nervous system.
- Degenerative and rheumatic joint diseases.
- Other diseases with limb paresis, paralysis, and musculoskeletal impairments.
- After injuries, following traumatic brain injuries or spinal cord injuries with limb paresis and paralysis, particularly with quadriplegia (as part of the rehabilitation process or as permanent orthopedic support).
CONTRAINDICATIONS
During standing process, the person being stood must be observed. In case of side effects such as paleness, sweating, or fainting, joint overloading and resulting body deformations, the therapy should be stopped. Further steps should be consulted with a specialist doctor or physiotherapist who prescribed the aid.
Absolute contraindication to standing therapy is the critical condition of the user.
Relative contraindications to standing therapy:
- resting arterial hypertension above 200/110 mmHg, pulmonary hypertension, heart rhythm disorders, unstable asthma, unstable metabolic disorders, moderate stage of heart valve disease.
- Any condition, such as healing fracture or severe osteoporosis, that prevents weight-bearing in any way.
- Fracture with incomplete healing, unless approved by a doctor.
- Postoperative joint load restrictions.
- Pain associated with standing in the stander (caused by dislocation or hip dislocation, excessive stretching of soft tissues, excessive pressure). Dislocation or dislocation of the hip joint without pain is not a contraindication.
People with significant flexion in the hip or knee joints, as well as with ankle joint contractures, may not be able to use the stander. Caution should be taken to ensure that the position in the device does not cause excessive pressure or stretching of the diseased areas of the body. In such cases, standing therapy may be contraindicated until a greater range of motion is achieved in the contracted joints.
For individuals with impaired circulatory system (resting arterial hypertension above 200/110 mmHg, pulmonary hypertension, heart rhythm disorders, moderate stage of heart valve disease); respiratory system (unstable asthma) and unstable metabolic disorders, close monitoring of the user during standing position is necessary to prevent serious complications. This includes particularly monitoring blood pressure, heart rate, and any symptoms of orthostatic hypertension.
How to Use
How to Measure
Downloads
Return and Refund
- Returns or exchanges are subject to applicable UAE law and the terms of this policy.
- For damaged, defective, incorrect or incomplete products, please contact us promptly for an assessment and the applicable refund, replacement or repair.
- For change-of-mind or customer-selected size returns, products must generally be unused, complete, in resaleable condition and in their original packaging with tags and hygiene seals intact.
- Hygiene-sensitive, worn, washed, contaminated, customised or individually fitted products may not be eligible for discretionary returns, but statutory rights for defective or incorrectly supplied products remain protected.
- Approved refunds are normally processed to the original payment method, with card refunds initiated within 15 working days and other refunds within 7 working days after the refund is confirmed.
Care Instructions
For care, use and maintenance, please follow the manufacturer's instructions in the brochure.
Download BrochureManufacturer's instructions and product information
Ratings & Reviews
FAQ’s About ACTIVALL Dynamic standing frame
Sizing, fitting, delivery and warranty — answered. Still unsure?
Ask our fitting team







Reviews
There are no reviews yet.